Biochemical Oxygen Demand (BOD) and Other Water Quality Indicators

Biochemical Oxygen Demand, or BOD, tells us how much oxygen tiny living things (bacteria and other microbes) use up while eating the dirt and waste in water. If water contains a lot of sewage, food waste or other organic matter, microbes feed on it and use up a lot of oxygen, so the BOD is high.

High BOD means dirty water. Along with BOD, scientists use a few other tests, such as COD, dissolved oxygen, faecal coliform, pH and suspended solids, to judge whether water is safe for drinking, bathing or fish.

Why do we need these tests?

You cannot judge water just by looking at it. Clear water can carry germs, and brown water may be only muddy. Governments need fixed, measurable numbers to decide three things: whether a river is polluted, whether a treatment plant is working, and who is to blame. Without such numbers, a court or a pollution board cannot fine anyone or check if a clean-up worked.

Why does oxygen matter so much?

Fish and other water animals breathe oxygen that is dissolved in water. This is called Dissolved Oxygen (DO). Clean river water at normal temperature holds only about 8 to 9 milligrams of oxygen per litre. When sewage enters, microbes start breaking it down and use up this oxygen. If DO falls below about 4 mg/l, fish struggle; near zero, they die. That is why high BOD leads to low DO, and why sudden fish deaths are a sign of a big sewage or waste load.

How is BOD measured?

A water sample is sealed in a bottle and kept in the dark at 20°C for 5 days. The oxygen in the bottle is measured at the start and at the end. The oxygen used up in those 5 days is the BOD, written as BOD₅ and measured in milligrams per litre (mg/l). Microbes would need about 20 days to finish eating all the waste, but 5 days is the standard short test.

  • Example: if the sample had 8 mg/l of oxygen on day 1 and 2 mg/l on day 5, its BOD is 6 mg/l.

The other key indicators, one by one

  1. Chemical Oxygen Demand (COD): The oxygen needed to break down all the waste in water using a strong chemical (usually potassium dichromate), not microbes. It catches waste that microbes cannot eat, such as many industrial chemicals. The test takes about 2 to 3 hours instead of 5 days. COD is usually higher than BOD, often 2 to 4 times higher for sewage.
  2. Dissolved Oxygen (DO): The oxygen actually present in the water. Here, higher is better.
  3. Faecal coliform: Bacteria that live in the gut of humans and warm-blooded animals. Finding them in water means human or animal excreta has entered it, so disease germs (like those causing cholera or typhoid) may also be there. It is counted as MPN per 100 ml (Most Probable Number of bacteria in 100 millilitres).
  4. Total Suspended Solids (TSS): Tiny bits of solid matter floating in water, like silt, sludge and particles of waste. They make water cloudy and block sunlight.
  5. pH: A scale from 0 to 14 that shows how acidic or basic water is. 7 is neutral. Most standards want river water roughly between 6.5 and 8.5.
  6. Ammoniacal nitrogen: Nitrogen present as ammonia, which comes mainly from sewage and industrial waste. It is toxic to fish and makes it hard and costly to treat river water for drinking.

How does India use these numbers? The "designated best use" classes

The CPCB sorts surface water into five classes, based on the best use the water is fit for:

Class Best use Main limits
A Drinking water source without conventional treatment but after disinfection Total coliform 50 MPN/100 ml or less; pH 6.5 to 8.5; DO 6 mg/l or more; BOD 2 mg/l or less
B Organised outdoor bathing Total coliform 500 MPN/100 ml or less; pH 6.5 to 8.5; DO 5 mg/l or more; BOD 3 mg/l or less
C Drinking water source after conventional treatment and disinfection Total coliform 5,000 MPN/100 ml or less; pH 6 to 9; DO 4 mg/l or more; BOD 3 mg/l or less
D Wildlife and fisheries pH 6.5 to 8.5; DO 4 mg/l or more; free ammonia (as N) 1.2 mg/l or less
E Irrigation, industrial cooling, controlled waste disposal pH 6.0 to 8.5; electrical conductivity 2,250 micromhos/cm or less; sodium absorption ratio 26 or less; boron 2 mg/l or less

For bathing water, the Primary Water Quality Criteria for Bathing (notified under the Environment (Protection) Rules, 1986) also set faecal coliform at 500 MPN/100 ml (desirable) and 2,500 MPN/100 ml (maximum permissible).

How does CPCB decide a river stretch is "polluted"?

CPCB checks water at fixed points under the National Water Quality Monitoring Programme (NWMP), run with the state pollution boards. As of 2025, this network had about 4,736 locations, including 2,155 on rivers. A stretch is marked polluted when its BOD is above 3 mg/l (the bathing limit). Polluted stretches are then ranked into five priority groups by BOD:

  • Priority I: BOD more than 30 mg/l (most polluted)
  • Priority II: 20 to 30 mg/l
  • Priority III: 10 to 20 mg/l
  • Priority IV: 6 to 10 mg/l
  • Priority V: 3 to 6 mg/l

The count of polluted stretches fell from 351 (2018 report) to 311 on 279 rivers (2022 report) and to 296 on 271 rivers (2025 report, based on 2022 to 2023 data). Priority I stretches fell from 46 (2022) to 37 (2025). The Yamuna's Delhi stretch remains in Priority I.

Standards for treated sewage

Rules also fix how clean the water coming out of an STP must be. In October 2017, the Ministry of Environment notified BOD limits of 30 mg/l (20 mg/l for metro cities and state capitals) and TSS limits of less than 100 mg/l (less than 50 mg/l for metros and capitals), with faecal coliform below 1,000 MPN/100 ml.

In April 2019, the National Green Tribunal (NGT) said these were too loose and ordered stricter, uniform norms for all of India: BOD below 10 mg/l, COD below 50 mg/l, TSS below 20 mg/l, and faecal coliform desirable below 100 and permissible below 230 MPN/100 ml. The Municipal Corporation of Greater Mumbai challenged this order in the Supreme Court [Unverified: current status of that challenge].

The legal base

The main law is the Water (Prevention and Control of Pollution) Act, 1974. Parliament passed it under Article 252 of the Constitution, because water is a State subject and states first passed resolutions asking Parliament to make the law. The Act created the CPCB and the State Pollution Control Boards. Section 24 bans putting polluting matter into a stream, well or sewer beyond the set standards.

The Water Amendment Act, 2024 replaced jail terms for most offences with money penalties: breaking Section 24 now attracts a penalty of ₹10,000 up to ₹15 lakh, plus up to ₹10,000 for each day the breach continues.

India's example: the Yamuna

The Yamuna's stretch in Delhi, from the Wazirabad barrage to the Okhla barrage, is about 22 km long, roughly 2% of the river's length, but carries an estimated 76 to 80% of its pollution load. Big drains such as the Najafgarh and Shahdara drains bring in untreated sewage and industrial waste. This explains two common sights:

  • Fish deaths, because high BOD drains the oxygen.
  • White toxic foam near the Okhla barrage and Kalindi Kunj, linked to detergents (phosphates), untreated sewage and ammonia, churned up by falling water at the barrage. High ammonia levels also force Delhi's drinking water plants to cut production, because the river water becomes too hard to treat.

Commonly confused concepts

  • BOD vs COD: BOD uses microbes and takes 5 days; COD uses a strong chemical and takes a few hours. COD covers all waste that can be oxidised, BOD only waste microbes can eat. So COD is usually the bigger number.
  • BOD vs DO: For BOD, lower is better. For DO, higher is better. A clean river has low BOD and high DO. Many students reverse this in the exam.
  • Total coliform vs faecal coliform: Total coliform includes bacteria from soil and plants too. Faecal coliform comes only from the gut of warm-blooded animals, so it is the sharper sign of sewage.
  • Class A vs Class C: Both are drinking water sources. Class A needs only disinfection (like adding chlorine); Class C needs full treatment first. Class A is the cleaner class, with the stricter limits.
  • STP vs CETP vs ETP: An STP (Sewage Treatment Plant) cleans household sewage. An ETP (Effluent Treatment Plant) cleans one factory's wastewater. A CETP (Common Effluent Treatment Plant) is one shared plant for many small factories in an industrial area.
  • Eutrophication vs algal bloom: Eutrophication is the process of a water body getting too rich in nutrients like nitrogen and phosphorus. An algal bloom is one result: a sudden thick growth of algae, which later dies and rots, pulling down oxygen even more.

Issues, criticism and the way forward

  • Treatment gap: India's cities produce more sewage than their STPs can treat, and many STPs run below capacity or break down. A plant on paper does not clean a river.
  • Rare and late testing: Quarterly sampling misses short spikes, such as night-time dumping by factories. Real-time sensors with live data, as the Supreme Court has now ordered, aim to fix this.
  • Data tampering: Self-reported data can be manipulated. Tamper-proof meters, calibration and treating data gaps as non-operation are ways to make data trustworthy.
  • Too few indicators: Using mainly BOD to mark polluted stretches can miss heavy metals, pesticides and microplastics, which BOD does not measure.
  • Blame across borders: A river like the Yamuna flows through several states. Measuring water quality where a river enters and leaves each state, as the court has ordered, makes it possible to fix responsibility.
  • Way forward: Expert bodies suggest treating and reusing sewage, connecting every house to sewer lines, keeping a minimum natural flow (environmental flow) in rivers, and decentralised treatment near the source.

Concepts to Know

  • Organic matter: Material that comes from living things, such as human waste, food waste and plant matter. Microbes can break it down.
  • mg/l (milligrams per litre): How many milligrams of a substance are present in one litre of water. 1 mg/l is the same as 1 part per million (ppm).
  • Disinfection: Killing germs in water, usually by adding chlorine or using ultraviolet light.
  • Conventional treatment: The normal steps in a water treatment plant: settling, filtering and then disinfecting the water.
  • Barrage: A low wall-like structure across a river, with gates, used to control and divert the river's water.
  • Environmental flow: The minimum amount of water that must flow in a river to keep it alive and healthy.
Key details
  • BOD test: oxygen used by microbes in 5 days at 20°C (BOD₅), in mg/l; high BOD = more organic pollution
  • COD: chemical (potassium dichromate) test, about 2 to 3 hours; usually 2 to 4 times BOD for sewage
  • CPCB classes: A (drinking, after disinfection only; BOD 2 mg/l or less, DO 6 mg/l or more), B (bathing; BOD 3 mg/l or less, DO 5 mg/l or more), C (drinking, after conventional treatment; BOD 3 mg/l or less, DO 4 mg/l or more), D (wildlife and fisheries), E (irrigation, industrial cooling)
  • Bathing criteria: faecal coliform 500 (desirable) and 2,500 (maximum permissible) MPN/100 ml
  • Polluted stretch: BOD above 3 mg/l; Priority I = BOD more than 30 mg/l
  • Polluted stretches: 351 (2018) → 311 on 279 rivers (2022) → 296 on 271 rivers (2025); Priority I: 46 (2022) → 37 (2025)
  • NGT STP norms (April 2019): BOD below 10, COD below 50, TSS below 20 mg/l; faecal coliform desirable below 100, permissible below 230 MPN/100 ml
  • Water Act, 1974: passed under Article 252; Section 24 bans discharge of polluting matter; 2024 amendment: penalty ₹10,000 to ₹15 lakh
  • Yamuna in Delhi (Wazirabad to Okhla): about 22 km, about 2% of length, about 76 to 80% of pollution load